© Oroflam s.r.l. 2011
18 mm
3 x 0.75 H03 / 3 x 0.75 H05
250 V
4 x 0.75 H03 / 4 x 0.75 H05
+5°C ÷ +55°C
- 20°C ÷ +55°C
Nylon PA6
1 kW
IP 54
18 mm
5.8 mm
Straight fast-on 6.3 x 0.8 mm
6.3 mm
-20°C ÷ +80°C
Nylon PA6
IP 54
QRx3 plug
QRx4 plug
M3
M3
Oroflam s.r.l. designed the QR type square plugs. These square plugs can be
supplied with or without cable and the cable can be 3-poles or 4-poles. The electric
connections can be oriented in conformity of the customer demand. The electric
connection is done by straight fastons and the plug is fixed to the tap with a cross
head M3 screw.
Wiring the plug is easy because the closing of the plug is done clutching it on itself.
The cable length, if it is required, and the type of electric terminals are in
conformity of the customer demand: we suggest you to contact our firm at the e-
mail address:
tecnico@oroflam.it
to have an offer for our plugs cabled in
conformity of your specifications using the drawings here below to specify us the
cable length, unsheathing dimension and the cable type, remembering to specify
also the electric terminals you need.
Note: the grounding orientation is defined by the third letter of the plug code: S =
south, N = north, E = east, O = west (please see the drawings here below).
QRxx (cabled square plugs) Technical Characteristics Table
Contacts distance
Maximum voltage
Maximum admittable continuous electric power
Electric cable QRx3 plug type
Electric cable QRx4 plug type
Protection class
Housing material
Ambient working temperature range
(moving installation)
Ambient working temperature range
(fixed installation)
Fixing screw
QRx (plugs without cable) Technical Characteristics Table
Contacts distance
Fitting electric terminals
Maximum electric cable jacket diameter QR3
Maximum electric cable jacket diameter QR4
Protection class
Housing material
Ambient working temperature range
Fixing screw
Square Plug Codes
QR3
“
P
” imprinting plug without cable prepared for the 3 x 0.75 mm cable
QRS3
QRE3
QRO3
QRS4
QRN3
QR4
QRN4
QRE4
QRO4
“
P
” imprinting plug without cable prepared for the 4 x 0.75 mm cable
“
P
” imprinting plug with 3 x 0.75 mm cable
the grounding is south oriented
“
P
” imprinting plug with 3 x 0.75 mm cable
the grounding is north oriented
“
P
” imprinting plug with 3 x 0.75 mm cable
the grounding is east oriented
“
P
” imprinting plug with 3 x 0.75 mm cable
the grounding is west oriented
“
P
” imprinting plug with 4 x 0.75 mm cable
the grounding is south oriented
“
P
” imprinting plug with 4 x 0.75 mm cable
the grounding is north oriented
“
P
” imprinting plug with 4 x 0.75 mm cable
the grounding is east oriented
“
P
” imprinting plug with 4 x 0.75 mm cable
the grounding is west oriented
Privacy & Cookies